Flow Switch

Flow Switch
Product Detailed

Flow Switch
1.Material :SUS
2.MOQ:50 SETS
3.Delivery ; about 5 days
4.Vertical installed

Flow Switch



Stainless Steel Paddle Flow Switch

 

Tolerance ±15% of full scal
Media Temperature -30~110
Average Pressure Loss 0.01bar at Qmax.
Hysteresis depending on switch value, minimum 0.7 l/min.
Metering Substances Oil, Water, Gas, Air (If special substances, please declare)
Max Pressure 25bar (40bar could be custom-made)
Pipe Size DN10~DN80
Materials Brass or Stainless Steel

 

 

flow meter,electromagnetic flowmeter

 

FS10 electroomagnetic flowmeter is an inductive apparatus to measure the flow volume of electric medium in the tube.the flowmeter composes of sensor and converter,the flowmeter design is adopted of SCM built-in technology to realize digital inciting magnetism the SCM connects CAN bus-mastering in the electromagnetic flowmeter at the same to time.the electromagnetic flowmeter can not only be read straightly but also output 4-20mA current signal for purpose of memory,adjustment and control,the flowmeter is extensively used in industry technology and administration department such as chemical industry,environmental protection,metallurgy,medicine,paper making and water supply ,etc.

 

Functional characteristics

1The structure of flowmeter is simple,function is reliable because there are no transmission parts,the working lifetime is long.

2 there are no block and cut-off parts,so the phenomenon of pressure loss and liquid block is not existed.

3 there is no mechanical inertia,fast response,excellent stability,it can be applied on automatic inspection adjustment and program process system.

4 the preciseness of measure is free of physical data influence of medium varieties,temperature,viscidity,density and pressure etc.

5 the different configurations of both PTFE or rubber lining and electrical poles Hc,Hb,316L,TI etc can satisfy different medium requirements.

6 there are two models:integration and separation

 

 

In the normal industry application,it is better to set the measured medium speed as 2-4m/s,under the special situation,the minimum speed should be more than 0.2m/s and maxium speed less than 8m/s,if there are solid granules in liquid,the usual speed should be less than 3m/s for purpose to avoid the over-atrition between lining and electrical poles,for viscid liquid,the speed can choose as 2m/s,the fast flow speed makes for the automatic elimination of obstructive substance glued on poles,therefore improve the inspections preciseness.